About
The Agilent 8890 Gas Chromatography System is a high-performance, intelligent GC platform engineered for advanced, flexible, and high-throughput analyses. With browser-based remote control, a full-function touch screen, autonomous system diagnostics, and integrated Capillary Flow Technology (CFT), it delivers superior reliability and repeatability for complex workflows. Designed for rugged performance and smart operation, it supports multidimensional GC, cryogenic cooling, and a wide array of detectors including FID, TCD, SCD, and NCD, making it ideal for demanding applications in energy, environmental, and food safety testing.
Note: The price mentioned above is for reference only. Do not consider it for purchase. For the actual price and more product details, please contact us at +91 98508 70860, +91 84461 74263.
Key Features
-
Browser-Based Remote Access
-
Full-Function Touch Screen
-
Autonomous System Diagnostics
-
6th-Generation Microchannel EPC
-
Capillary Flow Technology (CFT)
-
Autoranging FID and Stable TCD
-
Multi-Detector Support Including SCD/NCD
-
GC/MS Platform Compatibility
-
Helium Conservation Module
-
Hydrogen Sensor Module Series 2
-
Smart Key Column Integration
-
Retention Time Locking (RTL)
-
My Green Lab ACT Label Certified
List No. R
Disclaimer: UNLESS OTHERWISE INDICATED, THE CONTENT OF THIS WEBSITE IS THE PROPRIETARY PROPERTY OF ITS OWNERS. However, trademarks, service marks and/or logos (called "marks") herein associated with the products listed on this website are the property of their respective owners. If they appear with the listed products, it is only used for the purpose of identification of those products. We do not claim any association with the mark owners, unless otherwise so specified. MEANING OF LIST NUMBER: R - Refurbished, PO - Preowned, U - Used, T - Trading, M - Own Manufactured, AD - Authorized Dealer of Original Equipment Manufacturer.
Unmatched Versatility and Detector SupportFeaturing up to four simultaneous detector channels, the Agilent 8890 GC accommodates multiple detector types, such as FID, TCD, NPD, ECD, and mass selective detectors. This flexibility enables laboratories to perform a wide array of analyses within a single workflow, ensuring adaptability across various industry requirements.
Precision Control and Fast ThroughputWith independent programming for up to three column ovens and ultra-fast heat-up capabilities to 450C, the 8890 GC ensures rapid temperature changes and steady performance. Autosampler compatibility and accurate oven temperature control (0.1C) guarantee both high-throughput and reliable reproducibility for demanding analytical needs.
Smart Connectivity and Integrated SafetyThe 8890 offers LAN, USB, RS232, and optional wireless connectivity, allowing for remote operation and effortless data storage onboards or within networked environments. Built-in leak detection, automated diagnostics, and electronic over-temperature protection maximize uptime and instrument safety in any lab setting.
FAQ's of Agilent 8890 Gas Chromatography System:
Q: How does the Agilent 8890 GC support simultaneous multi-detector analyses?
A: The Agilent 8890 Gas Chromatography System allows up to four detector channels to operate simultaneously, with support for various detectors such as FID, TCD, NPD, and mass selective detectors. This setup makes it possible to analyze different target compounds in the same run, increasing efficiency and data collection per sample.
Q: What autosamplers are compatible with the Agilent 8890 GC?
A: The 8890 GC seamlessly integrates with Agilent's 7693A and 7650A autosamplers, 8697 Headspace Sampler, and the PAL3 autosampler. This compatibility provides flexibility in sample introduction, accommodating a wide variety of sample types and throughput needs.
Q: When should I use independent column oven programming in my workflow?
A: Independent column oven programming is ideal when running different analytical methods or temperature profiles simultaneously. This feature enhances throughput and versatility, especially in labs managing multiple analyses that require specific thermal conditions for optimal separation.
Q: Where can I monitor and control the 8890 GC remotely?
A: The Agilent 8890 comes with remote connectivity via LAN and optional wireless modules, allowing users to monitor and control the system through an intuitive browser interface. This enables convenient access and management from virtually anywhere within your laboratory network.
Q: What process ensures sample safety and operational reliability?
A: The 8890 GC incorporates automatic leak detection with notification, electronic over-temperature protection, and automated diagnostic checks. These processes are built in to maintain safe, reliable operation and to protect both samples and the instrument.
Q: How does the system benefit from advanced data storage and software compatibility?
A: With both onboard and networked data storage, the 8890 GC ensures data integrity and simplified access. Compatibility with OpenLab CDS and other leading chromatography software enables streamlined data analysis, reporting, and full regulatory compliance.
Q: What are the main benefits of the 8890 GC for high-volume analytical laboratories?
A: The system's high-speed sample processing (up to 1200 samples/hour with autosampler), independent temperature control, multi-channel detection, and comprehensive automation features significantly speed up workflows. These benefits reduce manual intervention, enhance precision, and maximize laboratory productivity.