  • तापमान प्रतिरोध
  • Ambient operating, not specified
  • सटीकता
  • Wavelength accuracy: ±1.0 nm
  • बिजली की आपूर्ति
  • Mains powered
  • डिस्प्ले टाइप
  • External PC interface
  • स्पीड रेंज
  • Acquisition time: <6 seconds per sample
  • कंट्रोल टाइप
  • Software controlled
  • विशेषताएँ
  • Automated sample loading; Non-contact measurements; High throughput; Wide dynamic range; Integrated barcode reading; Sample tracking
  • शेप
  • Rectangular
  • टाइप करें
  • आयाम (एल* डब्ल्यू* एच)
  • 495 mm x 410 mm x 205 mm
  • उपकरण सामग्री
  • Aluminum, Stainless Steel
  • पावर
  • 100-240 V, 50/60 Hz
  • वोल्टेज
  • 100-240 Volts
  • मटेरियल
  • Metal and engineering plastics
  • एप्लीकेशन
  • Quantitative DNA, RNA, Protein Analysis; UV-Vis Spectroscopy; High-Throughput Sample Screening
  • Operating Humidity Range
  • Up to 80% (non-condensing)
  • Platform
  • Benchtop
  • Measurement Mode
  • Microvolume, cuvette compatible
  • Software Compatibility
  • Windows OS
  • Detection Method
  • UV-Vis absorbance
  • Weight
  • 15.5 kg
  • Pathlength Range
  • 0.03 mm to 2 mm (automatically selected)
  • Minimum Sample Volume
  • 0.5 µl
  • Sample Loading
  • Automated robotic arm
  • Detection Wavelength Range
  • 200 nm to 830 nm
  • Sample Throughput
  • Up to 96 samples per run
  • Integrated QC
  • Real-time sample quality assessment
  • Environmental Conditions
  • 10°C to 35°C operating temperature
  • Maintenance Frequency
  • Low, annual recommended
  • Compliance
  • ISO 9001, CE marked
  • Light Source
  • Xenon flash lamp
  • Communication Ports
  • USB, Ethernet
  • Optics
  • No moving parts, solid state
  • Data Output Format
  • CSV, PDF, direct database export
 
 

About

The Implen N120 is a state-of-the-art microvolume spectrophotometer designed for high-throughput nucleic acid and protein quantification in molecular biology and life sciences laboratories. With the ability to process up to 12 samples simultaneously, the N120 offers rapid, accurate absorbance measurements in the UV/Vis range using as little as 0.5 -L of sample. Ideal for genomic, proteomic, and biochemical workflows, this system minimizes sample consumption while maximizing reproducibility and data quality.


Note

The price mentioned above is for reference only. Do not consider it for purchase. For the actual price and more product details, please contact us at +91 98508 70860, +91 84461 74263

Key Features
  • Simultaneous measurement of up to 12 samples

  • Requires only 0.5 to 2 -L of sample volume

  • UV/Vis spectral range from 200-900 nm

  • Fast read times with high accuracy and reproducibility

  • No consumables or cuvettes required

  • Integrated touchscreen interface with intuitive software

  • Ideal for DNA, RNA, and protein quantification

  • Data export options via USB, Wi-Fi, or network connectivity


List No. R

Disclaimer

UNLESS OTHERWISE INDICATED, THE CONTENT OF THIS WEBSITE IS THE PROPRIETARY PROPERTY OF ITS OWNERS. However, trademarks, service marks and/or logos (called "marks") herein associated with the products listed on this website are the property of their respective owners. If they appear with the listed products, it is only used for the purpose of identification of those products. We do not claim any association with the mark owners, unless otherwise so specified.MEANING OF LIST NUMBER: R -Refurbished, PO - Preowned, U - Used, T -Trading, M - Own Manufactured, AD - Authorized Dealer of Original Equipment Manufacturer.








Fast, Automated High-Throughput Analysis

The IMPLEN N120 spectrophotometer is engineered for efficiency and speed, enabling the measurement of up to 96 samples per run. Its automated robotic arm handles sample loading, optimizing workflow and minimizing manual intervention. With acquisition times of under 6 seconds per sample and non-contact measurement, it significantly boosts sample processing rates in busy laboratories.


Reliable Measurements with Integrated Quality Control

Ensuring data integrity is paramount, and the N120 offers integrated real-time quality assessment. The solid-state, no-moving-parts optical system delivers consistent, accurate readings across a broad pathlength range (0.03 mm to 2 mm). The on-board QC continuously monitors sample quality, supporting reproducible, high quality results in each run.


Flexible Data Management and Compliance

Data from the N120 can be seamlessly exported in CSV or PDF formats and even directed to databases for LIMS integration. The spectrophotometer supports Windows OS software control and meets ISO 9001 and CE compliance standards, making it suitable for diverse regulatory environments in research, clinical, or industrial facilities.

FAQ's of IMPLEN N120 Microvolume High Throughput Spectroscopy:


Q: How does the IMPLEN N120 automate the sample measurement process?

A: The IMPLEN N120 uses an automated robotic arm for sample loading, enabling unattended analysis of up to 96 samples per run. The entire process is software controlled, ensuring efficient high-throughput operation with minimal manual handling.

Q: What types of samples and analyses is the N120 spectrophotometer suitable for?

A: This instrument is optimized for quantitative DNA, RNA, and protein analysis as well as UV-Vis spectroscopy and high-throughput sample screening, making it ideal for molecular biology, quality control, and diagnostic applications.

Q: When should maintenance be performed on the N120 spectrophotometer?

A: The instrument is designed for low maintenance and typically only requires annual servicing. Routine cleaning and simple quality checks are usually sufficient due to the solid-state, no-moving-parts design.

Q: Where can measurement data from the IMPLEN N120 be exported or stored?

A: Measurement results can be output in CSV or PDF formats, or directly exported to database systems for seamless data tracking, LIMS integration, and compliance documentation.

Q: What benefits does the integrated quality control provide during sample analysis?

A: Real-time sample quality assessment ensures only reliable data is recorded by flagging problematic samples instantly. This leads to higher reproducibility and confidence in the final results.

Q: How does the N120 ensure accuracy and reproducibility in measurements?

A: Accuracy is supported by its wavelength accuracy of 1.0 nm and an auto-selected pathlength range (0.03-2 mm). The solid-state optics with no moving parts minimize variability, while integrated barcode reading and sample tracking maintain traceability.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
मोबाइल number

Email

अधिक Products in अस्पताल उपकरण Category

Hitachi PMI Master Pro2 मोबाइल Spectrometer

मूल्य की इकाई : टुकड़ा/टुकड़ाs

आयाम (एल* डब्ल्यू* एच) : मिलीमीटर (mm)

मूल्य या मूल्य सीमा : आईएनआर

न्यूनतम आदेश मात्रा : 1

माप की इकाई : टुकड़ा/टुकड़ाs

प्रॉडक्ट टाइप : Portable XRF Analyzer for Regulatory Compliance and Environmental Testing

Merck Eppendorf C170i Cell Culture Incubator

मूल्य की इकाई : टुकड़ा/टुकड़ाs

आयाम (एल* डब्ल्यू* एच) : मिलीमीटर (mm)

मूल्य या मूल्य सीमा : आईएनआर

न्यूनतम आदेश मात्रा : 1

माप की इकाई : टुकड़ा/टुकड़ाs

प्रॉडक्ट टाइप : Fanless CO2 Incubator

Olympus Haag Streit Hi-R 1000, Hi-R 700 Microscope

मूल्य की इकाई : टुकड़ा/टुकड़ाs

आयाम (एल* डब्ल्यू* एच) : मिलीमीटर (mm)

मूल्य या मूल्य सीमा : आईएनआर

न्यूनतम आदेश मात्रा : 1

माप की इकाई : टुकड़ा/टुकड़ाs

प्रॉडक्ट टाइप : Motorized Microscope with Integrated Optics and Illumination System

Hitachi Chromatograph HPLC Chromaster High Performance Liquid

मूल्य की इकाई : टुकड़ा/टुकड़ाs

आयाम (एल* डब्ल्यू* एच) : मिलीमीटर (mm)

मूल्य या मूल्य सीमा : आईएनआर

न्यूनतम आदेश मात्रा : 1

माप की इकाई : टुकड़ा/टुकड़ाs

प्रॉडक्ट टाइप : HighPerformance Liquid Chromatograph (HPLC) System



इनोर्बविक्ट हेल्थकेयर इंडिया प्राइवेट लिमिटेड लिमिटेड
GST : 27AADCI6120M1ZH trusted seller