About
The Implen NP80 is a versatile all-in-one microvolume and cuvette spectrophotometer designed for precise quantification of nucleic acids, proteins, and other biomolecules. Combining microvolume and cuvette-based measurements in a single compact device, the NP80 supports a wide range of applications in molecular biology, biochemistry, and life sciences. It offers accurate results with minimal sample volume, intuitive software, and robust connectivity, making it an ideal solution for research labs seeking efficiency and flexibility.
NoteThe price mentioned above is for reference only. Do not consider it for purchase. For the actual price and more product details, please contact us at +91 98508 70860, +91 84461 74263
Key Features
-
Dual functionality: microvolume and cuvette mode in one unit
-
Microvolume sample requirement as low as 0.3 -L
-
Wavelength range: 200-900 nm (UV/Vis)
-
Integrated 7" touchscreen with pre-installed Implen software
-
Rapid data acquisition with high accuracy and reproducibility
-
No recalibration or maintenance required
-
Ideal for DNA, RNA, protein quantification, and optical density measurements
-
Data export via USB, Wi-Fi, LAN, or direct printing
-
List No. R
Disclaimer
UNLESS OTHERWISE INDICATED, THE CONTENT OF THIS WEBSITE IS THE PROPRIETARY PROPERTY OF ITS OWNERS. However, trademarks, service marks and/or logos (called "marks") herein associated with the products listed on this website are the property of their respective owners. If they appear with the listed products, it is only used for the purpose of identification of those products. We do not claim any association with the mark owners, unless otherwise so specified. MEANING OF LIST NUMBER: R - Refurbished, PO - Preowned, U - Used, T - Trading, M - Own Manufactured, AD - Authorized Dealer of Original Equipment Manufacturer.
All-in-One Flexibility for Modern LabsThe NP80 spectrophotometer caters to diverse workflows, featuring both microvolume and cuvette measurement modes. Its adaptability is ideal for life science research, biotech applications, and diagnostic testing, supporting small sample volumes with minimal waste. The integrated benchtop design maximizes lab space while offering high-sensitivity detection and rapid operation.
Precision and Speed Unmatched in SpectroscopyEquipped with a xenon flash lamp and advanced optics, the NP80 delivers reliable results in mere seconds. Wavelength accuracy of 1 nm and photometric accuracy of 1% ensure confidence in data integrity. Its fast scanning technology supports swift, accurate measurements for DNA, RNA, and protein quantification, critical for high-throughput labs.
User-Centric Interface and Data ManagementWith a built-in operating system and 7-inch color touchscreen control, the NP80 is entirely standalone-no external PC required. Built-in NanoPhotometer Control Software and on-board storage streamline data handling, while Ethernet, USB, and WiFi connectivity facilitate easy data sharing and device management. The intuitive interface accelerates workflow and reduces user training time.
FAQ's of Implen NP80 All-in-One Spectroscopy:
Q: How does the NP80 handle both microvolume and cuvette measurements?
A: The Implen NP80 features automatic detection and switching between microvolume (0.3-2.0 l) and cuvette (up to 3 mL) modes. Its auto-ranging path length (0.67 and 0.07 mm) and integrated cuvette holder allow seamless measurement of a wide range of sample volumes without manual adjustment.
Q: What benefits does the NP80 offer over traditional spectrophotometers?
A: Unlike traditional systems, the NP80 combines microvolume and cuvette functionalities in a single compact instrument, supports fast measurements under 4 seconds, requires only minimal sample amounts, and operates as an all-in-one device without needing an external PC. नेटवर्क connectivity and onboard data storage further improve usability.
Q: When should I use the microvolume mode versus cuvette mode?
A: Microvolume mode is optimal when working with scarce or precious samples, such as nucleic acids or proteins, needing only 0.3 to 2.0 l. Use cuvette mode for larger volumes (up to 3 mL) or routine absorbance measurements where more sample is available.
Q: Where can the NP80 be utilized within a laboratory?
A: Thanks to its compact benchtop design (215 x 305 x 210 mm), the NP80 fits easily into any research, diagnostic, or biotechnology lab. Its robust construction and ambient temperature operation enable flexible placement on laboratory workbenches or dedicated instrument stations.
Q: What is the data storage and export process with the NP80?
A: The NP80 includes comprehensive on-board data storage and is equipped with USB, Ethernet, and WiFi ports. This allows users to securely store, transfer, or share measurement data directly from the device, streamlining integration with lab information systems or external computers.
Q: How accurate are the NP80 measurements and what standards does it meet?
A: The NP80 delivers wavelength accuracy of 1 nm and photometric accuracy of 1%. It meets CE and RoHS safety and environmental standards, ensuring reliable and compliant operation in regulated laboratory environments.
Q: What is the main advantage of the NP80's built-in operating system?
A: The built-in operating system, with a 7-inch color touchscreen, allows direct instrument control and method execution, eliminating reliance on an external PC. This streamlines laboratory workflows, reduces clutter, and ensures that setup and operation are straightforward for users of all levels.