About Agilent 240FS AA Flame Atomic Absorption Instruments
The Agilent 240FS AA Flame Atomic Absorption Spectrometer delivers high-speed, high-precision elemental analysis by measuring multiple elements from a single sample aspiration. Utilizing Fast Sequential (FS) mode and optional Sample Introduction Pump Systems (SIPS), the 240FS increases laboratory productivity, reduces sample and gas consumption, and ensures accurate results with optimized precision controls. Designed for high-throughput labs, it supports automation and enhances workflow efficiency without compromising data quality.
Note: The price mentioned above is for reference only. Do not consider it for purchase. For the actual price and more product details, please contact us at +91 98508 70860, +91 84461 74263.
Key Features
-
Fast Sequential Mode
-
PROMT (Precision Optimized Measurement Time)
-
SIPS 10/20 Automated Sample Preparation
-
Mark 7 Atomization System
-
Online Internal Standard Correction
-
SpectrAA Method Cookbook
-
High Sensitivity Atomization
-
Multi-Element Analysis in Under 2 Minutes
List No. R
Disclaimer: UNLESS OTHERWISE INDICATED, THE CONTENT OF THIS WEBSITE IS THE PROPRIETARY PROPERTY OF ITS OWNERS. However, trademarks, service marks and/or logos (called "marks") herein associated with the products listed on this website are the property of their respective owners. If they appear with the listed products, it is only used for the purpose of identification of those products. We do not claim any association with the mark owners, unless otherwise so specified. MEANING OF LIST NUMBER: R - Refurbished, PO - Preowned, U - Used, T - Trading, M - Own Manufactured, AD - Authorized Dealer of Original Equipment Manufacturer.
Advanced Performance and EfficiencyThe Agilent 240FS AA enables fast sequential operation and multi-element analysis, achieving exceptional throughput and lowering sample turn-around times. Automated lamp selection, SIPS auto-dilution, and D2 background correction ensure both speed and accuracy. Suitable for trace-level element detection, it supports a wide array of laboratory workflows with minimal manual intervention, increasing laboratory productivity.
Comprehensive Safety and DurabilityThis instrument is engineered with essential safety features, such as flame on/off interlocks, pressure monitors, and drain overflow detection, ensuring secure operation at all times. Constructed from corrosion-resistant materials and high-grade plastics, it withstands harsh laboratory environments, while automated controls streamline user interaction for sustained operational reliability.
User-Friendly Control and Data ManagementEquipped with a digital color touchscreen and intuitive Windows-based software, the 240FS AA simplifies method setup, sample processing, and data management. Efficient connectivity via USB and LAN makes result sharing and remote monitoring straightforward. The software supports comprehensive QA/QC procedures and storage of analytical methods, empowering robust compliance and traceability.
FAQ's of Agilent 240FS AA Flame Atomic Absorption Instruments:
Q: How does the Agilent 240FS AA enhance sample throughput compared to conventional sequential AAS?
A: The Agilent 240FS AA features Fast Sequential (FS) operation and automated capabilities, enabling it to process samples up to 2.5 times faster than traditional sequential atomic absorption spectrometers. This is achieved through automatic lamp selection, advanced optics, and the Sample Introduction Pump System (SIPS), which together minimize downtime and boost overall analytical efficiency.
Q: What types of samples and industries is this instrument best suited for?
A: The 240FS AA is ideal for elemental analysis in a variety of sectors, including environmental monitoring, food safety, agricultural testing, mining, and clinical laboratories. It accommodates liquid samples requiring trace element detection, leveraging robust sample introduction and background correction for dependable results in complex matrices.
Q: When should operators use the SIPS auto-dilution feature, and what are its advantages?
A: Operators should use the SIPS auto-dilution system when handling samples with unknown or variable analyte concentrations. This feature automates sample dilution, reducing errors from manual preparation, increasing reproducibility, and enabling direct analysis of samples at varying concentration levels within a single run.
Q: Where can data from the instrument be managed and how is connectivity facilitated?
A: Data from the 240FS AA can be managed via its user-friendly Windows-based software, which allows method creation, result review, and QA/QC reporting. Connectivity is facilitated through USB and LAN ports, making it easy to integrate with laboratory information management systems and support remote monitoring or data transfer.
Q: What safety features are incorporated to protect users during operation?
A: Safety features include flame on/off interlocks, pressure monitors for flame gases, and drain overflow detectors. These systems automatically shut down or notify users of unsafe conditions, significantly reducing operational risks and ensuring laboratory safety compliance.
Q: How does background correction work in the Agilent 240FS AA, and why is it important?
A: The instrument uses both Deuterium (D2) and Self Reversal techniques for background correction. D2 correction compensates for non-specific absorbance and spectral interferences, while Self Reversal enhances correction for specific analytes. This dual approach ensures accurate, interference-free measurements, essential for trace-level determinations.
Q: What benefits does the microprocessor-controlled operation provide for users?
A: Microprocessor control ensures precise, automated management of all instrument functions-such as lamp switching, flame ignition, and data acquisition. This automation streamlines workflows, minimizes human error, and guarantees reproducible, high-quality analytical results with every run.